Wall / Closet / Attic Air Handlers

FWA-HW / FWA-AQ

View ProductDetails

FWA-HW / FWA-AQ

FWA-AQ (with installed pump)
FWA-HW (without installed pump)
Multi-Position, Heating Only

Features

Copper tube / aluminum fin coil
Factory installed filter
Blower door safety switch
Manual air vent on coil
Separate flow control module available (FWA-HW only)
120/24V relay/transformer

HBQB (High Efficiency)

View ProductDetails

HBQB (High Efficiency)

Upflow / Horizontal Air Handler
Heat Pump or DX - With Hot Water Heat
With Multi-Function Microprocessor

Features

Blower delays
Two speed fan operation
Installed circulating pump
Easy access check valve
Installed manual air purge valve
Piston type metering device
Blower door safety switch (except 60HBQB)
Factory installed filter
Primary and secondary drains
120/24V relay/transformer
Slide out hot water coil assembly
Convertible horizontal drain pan
 

HBXB-HW (High Efficiency)

View ProductDetails

HBXB-HW (High Efficiency)

Upflow / Horizontal Air Handler
Heat Pump or DX - With Hot Water Heat
With Multi-Function Microprocessor

Features

Blower delays
Two speed fan operation
Extra high efficiency "A" coil
Slide out hot water coil assembly
Convertible horizontal drain pan
Piston-type metering device (standard)
Manual air bleed port on HW coil
Factory installed filter
Primary and secondary drains
Separate flow control module available (see note 2)
Blower door switch (except 60HBXB-HW)
120/24V relay/transformer

CLP-AQ (Less Than 30" Tall)

View ProductDetails

CLP-AQ (Less Than 30" Tall)

Upflow, Closet Fan Coil
Heat Pump or DX - With Hot Water Heat

Features

Less than 30" tall
Ducted return from either side (must specify right or left)
Two speed fan operation
Installed circulating pump
Easy access check valve
Installed manual air purge valve
Installed cooling coil for right or left side return air (installs inside the cabinet)
120/24V relay/transformer
Includes wall hanger brackets
Factory installed R-410A TXV 
Factory installed filter (inside cabinet)

CLP-HW (Less Than 30" Tall)

View ProductDetails

CLP-HW (Less Than 30" Tall)

Upflow, Closet Fan Coil
Heat Pump or DX - With Hot Water Heat

Features

Less than 30" tall
Ducted return from either side (must specify right or left)
Two speed fan operation 
Installed cooling coil for right or left side return air (installs inside the cabinet)
120/24V relay/transformer
Includes wall hanger brackets
Factory installed R-410A TXV 
Factory installed filter (inside cabinet)

UC-HW (without installed pump)

View ProductDetails

UC-HW (without installed pump)

Upflow Closet or Wall Recessed Air Handler
Heat Pump or DX - With Hot Water Heat

Features

Sloped thermoplastic drain pan
Front or bottom return (kit required for bottom return)
Installed manual air purge valve
Blower door safety switch
Primary and secondary drains
Convenient electrical connections
Can be hung on a closet wall (kit required)
Factory installed filter
120/24V relay transformer

UCQB (with installed pump and timer)

View ProductDetails

UCQB (with installed pump and timer)

Upflow Closet or Wall Recessed Air Handler
Heat Pump or DX - With Hot Water Heat
With Multi-Function Microprocessor

 

Features

Automatic pump timer
Blower delays
Sloped thermoplastic drain pan
Front or bottom return (kit required for bottom return)
Installed circulating pump and easy access check valve
Installed manual air purge valve
Blower door safety switch
Primary and secondary drains
Convenient electrical connections
Can be hung on a closet wall (kit required)
Bottom return air (requires return air cover)
Factory installed filter
120/24V relay transformer

UCXQB (with installed pump and timer)

View ProductDetails

UCXQB (with installed pump and timer)

Upflow Closet or Wall Recessed Air Handler
Heat Pump or DX - With Hot Water Heat
With Multi-Function Microprocessor

 

Features

High Efficiency ECM Motor
Automatic pump timer
Blower delays
Sloped thermoplastic drain pan
Front or bottom return (kit required for bottom return)
Installed circulating pump and easy access check valve
Installed manual air purge valve
Blower door safety switch
Primary and secondary drains
Convenient electrical connections
Can be hung on a closet wall (kit required)
Factory installed filter
120/24V relay transformer

UCX-HW (without installed pump)

View ProductDetails

UCX-HW (without installed pump)

Upflow Closet or Wall Recessed Air Handler
Heat Pump or DX - With Hot Water Heat

Features

High Efficiency ECM Motor
Sloped thermoplastic drain pan
Front or bottom return (kit required for bottom return)
Installed manual air purge valve
Blower door safety switch
Primary and secondary drains
Convenient electrical connections
Can be hung on a closet wall (kit required)
Factory installed filter
120/24V relay transformer

VHBQB (Variable Speed)

View ProductDetails

VHBQB (Variable Speed)

Upflow / Horizontal Air Handler
Heat Pump or DX - With Hot Water Heat
With Multi-Function Microprocessor

Features

High efficiency, variable speed motor
Automatic pump timer
Blower delays
Installed circulating pump
Easy access check valve
Installed manual air purge valve
Blower door safety switch (except 60VHBQB)
Factory installed filter
Primary and secondary drains
120V motor - 24V control
Slide out hot water coil assembly
Convertible horizontal drain pan

VHBXB-HW (Variable Speed)

View ProductDetails

VHBXB-HW (Variable Speed)

Upflow / Horizontal Air Handler
Heat Pump or DX - With Hot Water Heat


 

Features

High efficiency, variable speed motor
Blower delays
Extra high efficiency "A" coil
Slide out hot water coil assembly
Convertible horizontal drain pan
Manual air bleed port on HW coil
Factory installed filter
Primary and secondary drains
Separate flow control module available (see note 2)
Blower door safety switch (except 60VHBXB-HW)
120V motor - 24V control

CLX-AQ (Less Than 30" Tall)

View ProductDetails

CLX-AQ (Less Than 30" Tall)

Upflow, Closet Fan Coil With ECM Motor
Heat Pump or DX - With Hot Water Heat

Features

High Efficiency ECM fan motor
Less than 30" tall
Ducted return from either side (must specify right or left)
Installed circulating pump
Easy access check valve
Installed manual air purge valve
Installed cooling coil for right or left side return air (installs inside the cabinet)
Fully insulated cabinet 
120/24V relay/transformer
Includes wall hanger brackets
Factory installed R-410A TXV 
Factory installed filter (inside cabinet)